i-on40 Installer Mode Programming
Page 63
1. You understand basic IP terminology.
2. You have obtained the necessary information from
your Internet Service Provider.
Unit Name
Use this option to store a unique name for the unit.
Polling IP Address
Key in the IP address of the remote polling engine. If
the ARC is not using a polling engine then leave this
option blank.
ARC IP Address
Use this option for the ARC’s main IP addresses. This
option provides two entries for storing a primary and
a secondary ARC IP address.
Account Numbers.
To store an ARC account number select Communications –
ARC Reporting – Account Numbers.
If you are programming a partitioned system then the
control unit gives you the opportunity to store an account
number for each partition. If you are programming a Part
Setting system then you can store one account number.
With CID reporting the system reports alarms using a
four digit account code.
With Fast Format reporting you can use four-, five- or
six-digit codes. The control unit pads five-digit codes to
six digits using a leading zero. The control unit leaves
four- and six-digit codes unchanged.
Note: If you need to add a letter to the account code
press the numbers keys repeatedly until the letter
you want appears on the display. See page 7.
Report Type
To choose the report type to send to the ARC select:
Communications – ARC Reporting – Report Type.
The report types available are: Fast Format, Contact ID,
SIA 1, SIA 2, Scancom SIA 3, Extended SIA 3, Contact ID
in SMS.
Fast Format Channels