i-on40 Installer Mode Programming
Page 35
Type: Active when: Assign to
Partitions?
Open/Close
(04)
The system is unset.
Inactive when the system
is set.
Yes
Alarm Abort
(05)
An alarm in the selected
partition has been aborted
by the user within the 90s
abort period. Deactivates
when the alarm is reset.
Yes
Technical
Alarm (06)
There is a technical alarm. Yes
Confirmed
Alarm (07)
There is a confirmed alarm.
Deactivates when the
system is reset.
Yes
RF Low
Battery (08)
A wirefree detector reports
a low battery. The output
remains active until all
detectors stop reporting
low batteries.
Yes
RF
Supervision
(09)
There is a supervision
failure on any radio zone.
The output remains active
until all supervision failures
are reset.
Yes
RF Jamming
(10)
The control unit detects
jamming. The output
remains on until all
jamming disappears.
No
RF Fault (11) There are any of the
following faults: RF Low
Battery, RF supervision, RF
jamming.
Yes