Appendix I i-on40
Page 96
Part Set Alarm Response: Siren +
Comms
(See Note 2)
Part Set Final Exit: Final exit
Part Set Entry Route: Entry Route
Strobe on Set: On
Strobe on Unset: On
FULL SET LINK
Partitions 2-4: No
SYSTEM OPTIONS
WIRED ZONE TYPE:
2 Wire FSL 2k2/4k7 (To comply with
EN50131 select this option manually
during initial power up.)
USER ACCESS:
PA keys active: No
Quick Set: No
(See Note 2)
Quick Omit: No
User code reqd: Yes
USER RESET
Zone Alarms: Yes (Note: This option
does not appear if DD243 Confirmation
is ON)
Zone Tampers: Yes (See Note 4.)
System Tampers: Yes
DD243 CONFIGURATION:
Confirmation: On (See Note 1, and Note
on page 51)
Confirmation Time: 30 mins
After Entry: 2 zones
Entry Keypad Lock: Off
Sounder: Unconfirmed
Siren on: Unconfirmed
Unconfirmed Reset: User
Confirmed Reset: User
INSTALLER NAME
Installer
INSTALLER CODE:
7890
KEYPAD TEXT:
i-on40
REMOTE NEEDS ENTRY:
Disabled
PA RESPONSE:
Audible
AUTO REARM:
Never
Note: This setting is required in order to
comply with EN50131.
SIREN DELAY:
0 min
SIREN TIME:
15 minutes
To comply with EN50131-1 Clause 8.6
minimum is 90s, maximum is 15mins.
ENTRY ALARM DELAY:
Enabled
Note: This setting is required in order to
comply with EN50131 8.3.8.2.
SUPERVISION:
On
JAMMING:
On
FORCE SET:
Off
TAMPER OMIT:
Disabled
(See Note 2)
CSID CODE
0000
SILENCE ALERTS:
User Code
MAINS FAIL DELAY:
0 minutes (see Note 2)
COMMUNICATIONS
ARC REPORTING:
Note: to comply with EN50131 you
must fit a communicator module.
Call Mode: Enabled
(See Note 2)
Phone book: empty
Account Number: 000000
Report Type: Fast Format
Fast Format channels:
Output 1: Fire
Output 2: Panic alarm
Output 3: Burglar
Output 4: Open / Close
Output 5: Omit (System)
Output 6: Alarm Abort
Output 7: Alarm conf
Output 8: Technical Alarm
CID/SIA Events:
Fire: Yes
Panic: Yes
Burg: Yes
Technical Alarm: No
Tampers: Yes
Set/Unset: Yes
(See Note 2)
Part Set: Yes
(See Note 2)
Reset: Yes
(See Note 2)
Exit timeout: Yes
Omit: Yes
RF Supervision: Yes
RF Jamming: Yes
(See Note 2)
RF Battery/PSU: Yes
(See Note 2)
Panel Battery: Yes
(See Note 2)
Mains Fail: Yes
(See Note 2)
Faults: Yes
(See Note 2)
Installer Mode: Yes
(See Note 2)
User Code Changed: No
Date/Time Reset: No
Downloading: No
Restorals:
Enabled
Send tamper as burg:
Disabled
Dynamic Test Call: