Installer Mode Programming i-on40
Page 26
5. Press Y on the i-on40 keypad to confirm that the Info
Module has learned the identity of the i-on40.
Disabling Info Modules
If you physically remove the Info Modules from a system
(for example, when a user no longer requires them) then
you may wish to stop the control unit trying to update the
Info Module’s display. The Detectors/Devices–Info Module
menu provides the Updates option for this purpose.
To disable updates on an Info Module:
1. Select Detectors/Devices – Info Module - Updates.
The bottom line of the display shows either
“Disabled” or “Enabled”. (A “*” at the beginning of
the line shows the option currently in use.
2. Press u or n to select the option you require.
When you select Enabled, the control unit carries on
transmitting to the Info Module.
When you select Disabled, the control unit stops
transmitting data to all the Info Modules.
3. Press Y to confirm the change.
The default setting for this menu option is Disabled. The
control unit changes the setting to Enabled when you
teach an Info Module the control unit’s identity.
Enabling the Ready to Set LED
The Info Module possesses a LED that glows when the
alarm system is NOT ready to set (for example, because
a detector is reporting an alarm). To disable or enable
this LED:
1. Select Detectors/Devices – Info Module - Ready-to-Set
LED.
The bottom line of the display shows either
“Disabled” or “Enabled”. (A “*” at the beginning of
the line shows the option currently in use.
2. Press u or n to select the option you require.
When you select Enabled, the control unit carries on
using the Ready to Set LED on the Info Module.