Installer Mode Programming i-on40
Page 54
Web Server you must key into the Username field the
same text as you have programmed into the Installer
Name field.
Installer Code
The default Installer access code is 7890. Cooper Security
Ltd recommend that you change this code to some other
number. To change the Installer access code select
System Options-Installer Code.
The Installer code allows you to enter the Installer Menu,
and carry out an Installer reset. However, the Installer
code does not allow you to set or unset the system.
When logging into the i-on40 Web Server you must key
into the password field the same code as you have
programmed into the Installer Code field.
Keypad Text
If required the installer can key in a text message that
appears on the first line of the display in the standby
screen. This could be, for example, the name of the
installer’s company. See page 7 for hints on editing text.
Remote needs Entry
Instead of using an entry timer triggered by a Final Exit
zone to allow the user to gain access to the control unit
and unset the system, the user can employ a remote
control. To chose between either of these options select:
System Options – Remote needs Entry. The options available
are:
Enabled:
The user must first trigger an entry zone and start
the entry timer before unsetting the system with a
remote control.
Disabled:
The user can unset the system using a remote control
without first starting the entry timer.
PA Response
During a PA alarm the control unit starts communications
(provided you have a communication module fitted and