Cooper Security i-on160EX Installationsanleitung Seite 65

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 180
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 64
i-on160 Installer Menu Options
Page 59
At the end of the calendar set warning time the control unit stops the warning
tone, sets the affected partition(s) without any further delay, deactivates any
“Autoset Warning” outputs and activates any “Set” outputs. The system logs a
calendar set as “system auto set” along with the affected partition number.
Deferring Setting. During the calendar set warning time a user can interrupt
or cancel the setting process. To do this they must key in their access code at
a keypad (or present a prox tag) and select either “Defer” or “Cancel”. Note
that the user must belong to the partition that is due to be set.
If the calendar set warning timer has been defered by a user, the control unit
halts the warning timer, and defers any consequent setting event for 30
minutes. After 20 minutes the control unit starts counting down the warning
timer again from 10 minutes. Users can defer a calendar set in this way a total
of three times. After the third deferral the control unit will set the system.
If a user presses X twice. The first press will start the system setting, the
second press will cancel the setting process and take the system back to the
calendar set warning tone.
Note that deferring setting does NOT defer any unsetting events.
If the user cancels a calendar set, then the system waits until the next
programmed event that calls for setting the system or any partitions.
If There Is a Setting Fault. If there is a fault that would normally prevent
the system from setting then a calendar set event will also fail. Ten minutes
before the time for a setting event the control unit will start the calendar set
warning tone as usual, but at the setting time the control unit will not set the
system. The control unit will log the failure as “set fail”. At the same time the
control unit will activate any output programmed as type “Set Fail”.
Unsetting Events. When the control unit reaches the time programmed for an
unsetting event the control unit unsets all partitions programmed to unset.
There are no specific warning indications for partitions unset by a calendar
event.
Manual Setting/Unsetting and Calendar Sets. If a user sets a partition
that is due to be set by a Calendar event, then the partition remains set when
the calendar event time is past. Likewise, if a user unsets a partition before a
calendar event is due to unset the partition then the partition remains unset.
Manually setting and unsetting partitions controlled by Calendar Sets will not
alter the times programmed in Calendar events.
Restrictions on Calendar Sets
Please remember the following points when setting up events:
1. You cannot program an event to change the system/partition directly from
one part set level to another. You must program an event to unset the
system/partition first, and another event to set the system/partition to a
different part set level. For example, if event A part sets the system (or a
partition) then you cannot program event B to full set the system. You must
program event B to unset the system and then use event C to full set the
system.