i-on160 The Installer Menu
Page 29
CID/SIA Events
Fire: Yes
Panic: Yes
Burg: Yes
Technical Alarm: No
Tampers: Yes
Set/Unset: Yes (see Note 2)
Part Set: Yes(see Note 2)
Reset: Yes (see Note 2)
Exit timeout: Yes
Omit: Yes
RF Supervision: Yes
RF Jamming: Yes (see Note 2)
RF Battery/PSU: Yes (see Note 2)
Panel Battery: Yes (see Note 2)
Mains Fail: Yes (see Note 2)
Faults: Yes (see Note 2)
Installer Mode: Yes (see Note 2)
User Code Changed: No
Date/Time Reset: No
Downloading: No
1. Appears when Report
Type=CID or SIA.
2. This setting is required in
order to comply with
EN50131.
Restorals
Enabled Appears when Report
Type=CID or SIA.
Burg Comms Rearm
Disabled Appears only when Report
Type=Fast Format.
21CN FF Ack time
800ms Appears only when Report
Type=Fast Format.
Send tamper as burg
Disabled Appears when Report
Type=CID or SIA.
Dynamic Test Call
Enabled
Static Test Call
Disabled Appears only when Report
Type=Fast Format.
To comply with EN50131,
either Static or Dynamic test
calls must be enabled. This is
available only when an i-sd02
is fitted and ARC
Communications enabled.
Speech Dialler
Only visible when suitable
communications module fitted.
Call Mode
Disabled
Messages
None
Phone Book
Empty
Triggers
None
Destinations
None
Call Acknowledge
Enabled
SMS
Only visible when suitable
communications module fitted.
Call Mode
Disabled
Messages
Blank
Phone Book
Empty
Triggers
None
PSTN SMS
Protocol
TAP 8N1
Service Centre Tel
07860980480 O2-UK
Line Fail Response
Audible Only visible when suitable
communications module fitted.
Line Fail Delay
9s This setting is required in
order to comply with
EN50131.
Only visible when suitable
communications module fitted