i-on160 Appendix II
Page 157
To avoid false alarms make the alarm response of the common area (Partition
1) Siren + Comms and the other two Partitions Siren only.
Zone Programming
Location Zone Name Zone Type Partitions
Front Door 001 Front Door Final Exit P1
Foyer PIR 002 Foyer PIR Entry Route P1
Loading Bay Entrance 003 LB to Foyer Final Exit P2
Roller shutter 004 Rshutter Normal Alarm P2
Loading Bay PIR 005 LBay PIR Entry Route P2
Factory PIR 006 Factory PIR Normal Alarm P2
Factory Fire Door 007 Factory FD 24 Hour P2
Kitchen PIR 008 Kitchen PIR Normal Alarm P1
Office Fire Door 009 Office FD 24 Hour P3
Office PIR 010 Office PIR Normal Alarm P3
Reception PIR 011 Recpt PIR Entry Route P3
Reception Entrance 012 Rcept Door Final Exit P3
Partition and Other Programming
Menu Sub Menu Option
Add/delete Detectors/Devices External Radio Siren (if to be fitted)
Wired keypads Keypad 01 Name = Office
Partition 3
Keypad 2 Name = Factory
Partition 2
Keypads 3 & 4 – not
fitted
NA
Outputs Panel Outputs 1 = Siren
2 = Strobe
3 & 4 = NU
Partitions P1 Name = Foyer
Exit Mode = Final Door Set
Settle Time = 10s
Entry Time = 45s
Alarm Response = Siren + Comms (Full)
Strobe on Set = Yes (If required)
Strobe on Unset = Yes (if required)
P2 Name = Offices
Exit Mode = Timed
Exit Time = 20s
Entry Time = 45s
Alarm Response = Siren (Local)
P3 Name = Factory
Exit Mode = Timed
Exit Time = 20s
Entry Time = 45s
Alarm Response = Siren (Local)
Full Set Link P2 = Yes
P3 = Yes