i-on160 The System Bus
Page 15
Delete the device information from within the control unit. Each type of
device has its own “delete” command in the Installer menu.
Reset the bus address on the device to zero.
See page 99 for detailed instructions on adding and deleting bus devices.
If a bus device is damaged and you suspect it is faulty then you can use the
Installer menu to temporarily disable the device. The control unit will ignore
any input from the device while it is disabled, and not send any output
commands to the device. When the time comes to replace the damaged device
then the Installer menu provides a “Replace” command that you can use to
swap out the damaged unit for a new one, retaining all the device information
from the old unit. See page 105 for detailed instructions on disabling and
replacing bus devices.
Bus Device Addresses
The control unit reports the addresses of bus devices as two groups of
characters, separated by a “-“:
An-dd
A = A letter showing the device type: P=panel, K=keypad, W=Wired
Expander, R=Radio Expander, O=Output Module.
n = Bus number. In an i-on160EX the bus number is always 1.
dd = Bus device number. In an i-on160EX this can be any number 01 to 99
(but there can only be a total of 45 devices).
Expanders always have bus device numbers in the range 01 to 49. Keypads
and output modules always have bus device numbers in the range 51 to 97.
Figure 3 shows an example of how the control unit in a small system might
address each device attached to the bus. The system has two 10-zone
expanders and three keypads. Each device has one address.
Figure 3. Bus Device Addressing Example
The EXPR-30 is a bus device that uses more than one device address. In Figure
4 the second expander on the bus is an EXPR-30. The EXPR-30 always takes
three consecutive bus device numbers. In Figure 4 the control unit gives this
one device the numbers R1-02, R1-03 and R1-04. In the Installer menu the
keypad display shows only “R1-02” but also adds the characters “(R30)” at the
end of the line as a reminder.
MENU
A
B
1
4 ghi
7 pqrs
*
0
#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*
0
#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
MENU
A
B
1
4 ghi
7 pqrs
*
0
#
2 abc
5 jkl
3 def
6 mno
8 tuv 9 wxyz
K1-51
W1-01
R1-02
K1-52 K1-53
EXPW10
(wired expander)
EXPR-10
(radio expander)
Seitenansicht 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 179 180

Kommentare zu diesen Handbüchern

Keine Kommentare