4. Programming
496964 Page 89
80: Forbikobler Chime
This Command links the bell push on the Forbikobler keypad to the Chime on
the system, so that pressing the bell operates the sounders.
Option
0 Off. Pressing the bell push does not operate the sounders (default).
1 On. Pressing the bell push operates the sounders.
Note: This is not available in a partitioned system.
81 to 84: Output n Type
Note: Command 84 applies only to the 9851, as only it has a fourth output.
These Commands program the control unit's panel outputs. They take two
digits to select the output type (see below) and have the following defaults:
Command Output Control unit Default outputs
81 1 All 00 Bell
82 2 All 08 Strobe
83 3 All 03 Set Latch
84 4 9851 03 Set Latch
Option
00 Bell: active during an alarm. Use Command 41 to set Bell Delay and
42 to set Bell Duration. In a partitioned system, this type is activated
when any partition is in alarm. If Alarm Confirmation (Command 89) is
enabled, use Command 162 to set whether the bell is sounded on the
first or confirmed alarm.
01 EE Follow: active when Entry or Exit Time starts and inactive when
the time expires or is terminated. The output can be used for a
separate Entry/Exit buzzer. It will not give a tone during part set if the
exit mode is silent set or instant set.
02 Armed Lamp: active continuously while the system is full or part set.
03 Set Latch: active when the system is set and inactive when the
system is unset or an alarm condition occurs. It is active for one
second when a reset is performed or the control unit leaves
programming mode. It is also active during Walk Tests.
04 Shock Reset: used to reset shock sensors (for example, the "Viper").
The output is triggered by the control unit at the start of the Exit Time
and remains active for five seconds.