4. Programming
Page 108 496964
144 to 150: Not used
These commands are not used.
151 to 158: Plug-by Communicator Outputs
The main circuit board of the control unit provides eight programmable
outputs that can be used to control a plug-by communicator. The outputs can
be connected to the communicator by an twelve-way wiring harness provided
with the control unit. See "3. Installation – Fitting a Plug-by Communicator" for
details of the wiring harness.
Commands 151 to 158 allow you to assign one of several channels to each
output. Command 151 controls output 1, 152 output 2 and so on, up to
Command 158 which controls output 8. Each Command has the same options
(23-26 apply to a partitioned system only):
00 Not Used 19 Smoke Detector
01 Fire 20 Comms Acknowledge (see Note)
02 PA 21 Battery Fault
03 Burglar 22 System Alarm
04 Open/Close 23 Alarm Partition 1
05 Alarm Abort 24 Alarm Partition 2
06 Technical Alarm 25 Alarm Partition 3
07 Alarm Confirmation 26 Alarm Partition 4
08 RF Low Battery 27 Not used
09 Supervision Loss 28 Not used
10 RF Jamming 29 Not used
11 AC Fail 30 Pulse Set OP 1
12 Tamper Alarm (day tamper) 31 Pulse Set OP 2
13 Open 32 Pulse Set OP 3
14 Close 33 Pulse Set OP 4
15 Zone Omitted 34 Pulse Unset OP 1
16 Medical Assistance 35 Pulse Unset OP 2
17 Key Box 36 Pulse Unset OP 3
18 Anti-Mask 37 Pulse Unset OP 4