4. Programming
496964 Page 103
126: Select Language
The control unit can display messages on the keypads in several languages.
Select option for the language you wish to use:
0: English (default) 6: Deutsch (German)
1: Italian 7: (NO) (Norwegian)
2: Espanol (Spanish) 8: (SV) (Swedish)
3: Port (Portuguese) 9: (DK) (Danish)
4: Nederl (Dutch) X1: (SF) (Finnish)
5: Francai (French)
Note: This overrides the default language loaded when the Country is selected
with Command 0.
127: Not used
This command is not used.
128: Radio Zone Supervision Fail Response
If the system is fitted with a radio expander, all radio zones are supervised. If
a radio zone does not communicate with the expander for one hour or more,
the expander reports a supervision failure to the control unit. This Command
specifies how the control unit responds to the reported supervision failure.
In all cases, the failure is reported on the keypad display. The failure message
is cleared when the zone is reinstated.
Option
0 Full alarm (all sounders and communication to the ARC)
1 Internal, external and keypad sounders
2 Keypad sounders only
3 Communication to the ARC and no sounders
4 Keypad sounders and the control unit will not set until the faulty radio
detector responds to supervision