5. Testing
Page 130 496964
To print a listing of the control unit's configuration, key in 90 8 Y.
Note: 975x models do not have the connector required for event log printing.
Event Log Messages
* Printed event messages start with a time and date stamp.
Keypad Display Printed (9851 only)* Meaning
AC Fail AC Lost Mains supply failed
AC Restore AC Restore Mains supply restored
Al Conf Dis Knn Al Conf Dis KEYPAD Alarm confirmation disabled by lock
switch
Alarm Abort USER Alarm Abort User aborted alarm
Al Confirm Znn Confirmed Znn Confirmed alarm on zone nn
AntiMask Al Znn Anti Mask Alarm ZONE Anti Mask alarm on zone nn
AntiMask Rs Znn Anti Mask Restore ZONE Anti Mask zone nn restored
AntiMask Tp Znn Anti Mask Tamp. ZONE Tamper on antimask zone nn
AUX DC Fail AUX Trouble Auxiliary power failed
AUX DC Fail Rstr AUX Restore Auxiliary power restored
Bad Checksum EEPROM Failure The control unit has detected data
corruption in its memory
Batt Flt Rstr Battery Restored Battery re-connected
Batt Load Fail Batt Load Test Fail Battery failed load test
Batt Missing Battery Missing Batter disconnected
Bell Tamper Rst Bell Tamper Restore Tamper on bell restored
Bell Tamper Bell Tamper Bell tamper
Burg Znn Alarm Burg: ZONE Intruder alarm on zone nn
Burg Znn Rstr Burg Restore ZONE Intruder alarm on zone nn restored
Codes Defaulted Passwords Loaded User access codes and installer code
returned to default values
Comms Fail PlugOn Coms Fail (9851) Communication failure
Defaults Loaded Defaults Loaded All programming defaults loaded
EEPROM Fail EEPROM Bad Data Control unit memory damaged
Exp nn Tamper Exp. Tamper Expander tamper alarm
Exp nn Tamp Rst Exp. Tamper Restore Expander tamper alarm restored
Expander nn Miss Expander Missing Expander disconnected
Expander nn Rest Expander Restored Expander reconnected
Fire Reset USER Fire Reset Fire alarm on zone nn reset
Fire Znn Alarm Fire ZONE Fire alarm on zone nn
Fire Znn Rstr Fire Restore ZONE Fire alarm on zone nn restored
Global T. Restore Global T. Restore Global zone tamper alarm restored
Global Tamper Global Tamper Global zone tamper alarm
Knn Excess Keys Tamper Usercode KEYPAD User has tried to enter access code too
many times on keypad nn
Knn Missing K/P Missing KEYPAD Keypad nn disconnected
Knn Restore K/P Miss Restore KEYPAD Keypad nn re-connected