Cooper Security 9751 Installationshandbuch Seite 135

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 148
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 134
4. Programming
496964 Page 127
The table below summarises which options to select on various Commands in
order to comply with paragraphs 6.4.2 to 6.4.6.
DD243: 2002 Para: 6.4.2 6.4.3 6.4.4 6.4.5 6.4.6
Possible Installation
Command
Unset from
outside using
a keyswitch
zone input
Exit Mode
of "Lock
Set"
Keypad and
User access
code
Portable ACE
(with reader
inside
premises)
Requires
ARC to
unset
89 Alarm Confirmation
Enabled
160 Confirmation Time
30 to 60 minutes
48 Lockout Keypads
During Entry
No
(Option 0)
No
(Option 0)
No
(Option 0)
Yes
(Option 1)
No
(Option 0)
163 Confirmation on
Entry
Never
(Option 0)
Never
(Option 0)
Never
(Option 0)
Two zones
(Option 2)
Never
(Option 0)
164 User Reset After
Confirmation
Enabled
(Option 1)
Enabled
(Option 1)
Disabled
(Option 0 or 2)
Disabled
(Option 0 or 2)
Enabled
(Option 1)
Alarm Filtering
The IAS should either:
a) Have the means to indicate to the ARC whether the IAS is set or unset
(open and close signals).
or
b) Be capable of generating a secondary signal identifiable at the ARC as a
mis-operation signal (see Command 36 Alarm Abort ).