4. Programming
Page 84 496964
68: Forbikobler Door Timer
This Command sets the time that the Forbikobler system allows for entry to
the building (not the time needed to unset the system). During this period, an
optional output is activated to operate an electromechanical lock on the door.
Option
0 2 seconds
1 3 seconds
2 4 seconds
3 5 seconds (default)
4 10 seconds
5 20 seconds
6 30 seconds
7 60 seconds
8 120 seconds
9 255 seconds
69: Forbikobler Door Locking
This Command specifies whether the door controlled by the Forbikobler
system is normally unlocked while the system is reset or opened only for a
controlled time. Even if the door is normally unlocked, it can be locked with a
user command if required.
Option
0 Lock Timed (default)
1 Lock Toggled
70: Level C Final Exit Operation
In a single system, this Command specifies how the system treats Final Exit
zones during part set C. If you select option 0, any Final Exit zones included
in Level C continue to act as Final Exit zones during part set C. If you select
option 1, these zones act as Normal Alarm zones during part set C.
Note: This Command is not available in a partitioned system.