4. Programming
496964 Page 81
59: External Sounder Tamper
This Command specifies which one of two tamper arrangements is used to
connect the control unit to the external sounders.
Option
0 Tamper return uses negative voltage
1 Tamper return is terminated with a 2k2 resistance.
Select the appropriate option for the sounder fitted to the system.
60: Level B Final Exit Operation
In a single system, this Command specifies how the system treats Final Exit
zones during part set B. If you select option 0, any Final Exit zones included in
Level B continue to act as Final Exit zones during part set B. If you select
option 1, these zones act as Normal Alarm zones during part set B.
Note: This Command is not available in a partitioned system.
61: Level B Entry Route Operation
In a single system, this Command specifies how the system treats Entry
Route zones during part set B. If you select option 0, any Entry Route zones
included in Level B continue to act as Entry Routes during part set B. If you
select option 1, these zones act as Final Exit zones during part set B.
Note: This Command is not available in a partitioned system.
62: Level/Partition B Exit Mode
This Command sets the exit mode for Level or Partition B.
In a single system, the options are:
Option
0 The keypad sounders and any internal sounders give a low tone
during exit of Level B. Use Command 65 to select the exit time.
1 Instant Set (no exit tone)
2 Silent Set. Use Command 65 to program the Exit time. At the end of
the exit time the keypad gives a double "beep" confirmation tone.
3 Makes the Level B exit mode the same as Level A.