Programming Reference - Reporting 7510r
Page 62
If you select Enabled the for full alarm response the
control unit sends tampers as burglary (BA) and sends
Contact ID 130 in place of Contact ID 137.
Social Care Reporting
The control unit sends a social care alarm message for
the following types of alarm:
Emergency
A user presses a button on a pendant. The control
unit then reports to the social care station with an
EMERG BUTTON event (SCANCOM channel 2).
Activity
A zone with the Activity Monitoring attribute has been
triggered.
While the system is unset the control unit checks that
this zone is reporting activity. If the zone is quiet for
longer than a pre-programmed time (see page 73)
then the control unit starts a medical alarm and
reports to the social care station with an INACTIVITY
event (SCANCOM channel 3).
If the system is set then the Activity Monitoring zone
acts as a normal alarm.
The report sequence is as follows:
1. The control unit reports to the social care station if
social care reporting Call Mode is ON. The report
includes a SCANCOM channel 8 to show that a two
way speech path is available.
The control unit opens a two-way speech channel at
the end of the report and leaves it open until the
control unit receives a DTMF ‘5’ command or a
timeout occurs. The social care station can send
commands to the control unit by using DTMF tones
during the 2-way speech call. The commands
available are: