7510r Programming Reference - Other Devices
Page 31
Adding a WAM
To teach the control unit the WAM’s identity:
1 Select Other Devices – WAM – Add/Del WAM.
The display shows a list of available WAM modules
from WAM 1 to WAM 8. Each line is a “memory slot”
for learning the identity of a single WAM module.
When a slot is occupied with a WAM the then line
shows a “
” icon.
2. Select the memory slot that you wish to use.
(Table 1 shows the way that zones and outputs on
the WAM map onto zones and outputs on the control
unit. For example, WAM 8 zone 2 corresponds to
control unit zone 18, while WAM 8 output 4
corresponds to panel output 6.)
The display asks you to activate the tamper switch on
the WAM.
3. Activate the WAM tamper.
The WAM signals its identity to the 7510r control unit.
When the control unit learns the WAM’s identity it
gives a double beep.
ZONES OUTPUTS
WAM No. WAM Zone
No
Panel
Zone No
WAM
No.
WAM OP
No.
Panel OP
No.
1 (HW)
2 (HW)
1 1 3
2 2 4
3 3 5
4
8
4 6
5 1 7
6 2 8
7 3 9
8
7
4 10
9 1 11
10 2 12
11 3 13
12
6
4 14
13 1 15
14 2 16
15 3 17
16
5
4 18
1 17 1 19 8
2 18 2 20
1 19 3 21 7
2 20
4
4 22
1 21 1 23 6
2 22
3
2 24