4. System Configurations
497096, issue 3 Page 83
DD243: 2004 Compliance
Applicability
Please study this section if all of the following apply:
1. You are installing an alarm system in England, Wales or Northern Ireland.
2. The system has remote signalling and requires the local Police Authority to
issue a URN (Unique Reference Number).
3. You have chosen to use "Sequential Alarm Confirmation" to comply with
DD243: 2004.
For Installers in Scotland, the ACPOS-IAS policy document states:
"Confirmation technology (BS DD243 applies) is desirable for newly installed
systems but is not mandatory in terms of this policy."
Cooper Security therefore recommends that systems in Scotland are installed
to comply with DD243: 2004, and Installers obtain copies of the ACPOS policy
from their local Police Authority.
Note: The installed system will only fully comply with the requirements of DD243: 2004 if it
has been designed in accordance with this section.
Programming for Compliance
Use the following settings to ensure compliance with DD243: 2004.
Command Name Value Page Notes
33 System Reset 1 18 Engineer Reset. In addition various other forms of reset
can be used such as remote reset or anti-code (if the
CSID code has been programmed into the control unit).
81-84 Output types 36 There are three new output types that you can use to
indicate the status of the system: Alarm Confirm, Set
Complete and Unset Complete.
89 Alarm
Confirmation
1 39 Enabled
Note: The following commands are available only if Alarm Confirmation is enabled.
48 Lockout
Keypads During
Entry
1 24 Yes. Use this option to comply with section 6.4.5.
160 Confirm Time 30 59 Default.
161 Internal Sounder 0 59 Sounder on confirmed or unconfirmed alarm.
162 External
Sounder
0 60 Sounder on confirmed or unconfirmed alarm.
163 Confirm After
Entry
0 60 When a user starts the entry timer, the control unit
disables Alarm Confirmation. Use this option to comply
with sections 6.4.2, 6.4.3, 6.4.4 and 6.4.6.
2 60 The control unit starts a confirmed alarm if an intruder
activates two separate zones after the entry timer
expires. Use this option to comply with section 6.4.5.
164 User Reset After
Confirmed
Alarm
1 61 Enabled to enable users to reset the system after a
confirmed alarm.