2. Programming Commands
497096, issue 3 Page 41
99: Leave Installer Mode
This command returns to user mode (for more information, see page 3).
100: Not used
This command is not used.
101: Call Mode
Use this command to select the call mode used by the communicator when
contacting the Alarm Receiving Centre (ARC).
Option
0 Disabled (default). The control unit does not use any communications.
1 Single reporting. The control unit reports to one programmed
telephone number (see Command 115) with one account number (see
Command 117).
Operation: The communicator dials the number and tries to connect
with the ARC. If it fails, it closes down and then tries again. It will try to
connect up to 15 times.
2 Alternate reporting. The control unit reports to one of two programmed
telephone numbers (see Commands 115 and 116), still using one
account number (see Command 117).
Operation: The communicator dials the first telephone number and
tries to connect to the ARC. If it fails, it closes down, dials the second
telephone number and tries to connect to the ARC again. If this
attempt is received and acknowledged, the system closes down and
the alarm transmission is complete. If this attempt fails, the system
closes down and tries again to connect to the first telephone number.
The communicator tries the two numbers in turn for up to 15 times,
until it has successfully called one of them.
3 Dual reporting. The control unit reports to two programmed telephone
numbers, one each for two receivers (see Commands 115 and 116).
Operation: The communicator dials the first telephone number and
tries to connect to the first ARC. If this attempt is received and
acknowledged, the communicator dials the second number and tries
to connect to the second ARC. If this attempt is received and
acknowledged, the communicator closes down and the alarm
transmission is complete. If the call to the first number fails, the
communicator tries the second number. If the call to the second
number fails, the communicator closes down and tries the first number
again. The communicator tries the two numbers in turn for up to 15
times, until it has successfully called both of them.
Note: Dual reporting does not work with SIA or CID reporting formats.