2. Programming Commands
497096, issue 3 Page 19
37: Daytime Tamper Communication
This command defines how the control unit reports tamper indications (for
example, an attempt to open a control unit or keypad case) while the alarm
system is unset.
Option
0 Internal sounder only (default).
1 Internal sounder and communication of tamper indication to the Alarm
Receiving Centre (ARC).
Notes:
1. Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) at Grade 3 requires
that Command 37 is set to 1 (see notes for Command 132 on page 53).
2. Command 31 sets user/engineer reset for zone tampers.
3. Command 38 sets user/engineer reset for system tampers.
4. Command 58 sets user/engineer reset for system tampers.
38: System Tamper User/Engineer Reset
This command defines how to reset the control unit after a tamper alarm (for
example, an attempt to open a control unit or keypad case).
To require an engineer reset, select option 1 (the default). To permit a user
reset (provided that no tamper circuit is open), select option 0.
Note: This facility is independent of the options selected in Commands 31 and 33.