2. Programming Commands
497096, issue 3 Page 9
Value Type Description
05 Final Exit (FE) Zones of this type must be the first to be activated on entry. You
can use them to set the system using the Final Door Set exit
mode. Use Command 39 to set the exit mode for the zone (page
20). Use zone attribute X7 to select an entry timer for the zone
(page 12) and Commands 201–4 (page 66) to set up the entry
timers.
06 Entry Route
(ER)
Use this zone type for detectors sited between the Final Exit
door/detector and a keypad. If an "Entry Route" zone is violated
when the system is set, an alarm will occur. If the Entry/Exit
timer is running when an Entry Route zone is violated, no alarm
occurs until the Entry/Exit timer expires. Use zone attribute X7 to
select an entry timer for the zone (page 12) and Commands
201–4 (page 66) to set up the entry timers.
07 Shock
Analyser (SA)
You can apply this zone type to zones 1 to 4. The system will
not accept this type for zones 5 to 40. Use zone attribute X7 to
set the sensitivity for the zone (page 12).
08 Technical
Alarm (TC)
Use this zone type when you want to monitor equipment, for
example a freezer, without raising a full alarm. If a Technical
Alarm zone is activated while the system is set, the system
makes no audible alarm. However, when a user unsets the
system, the keypad indicates a fault. If a Technical Alarm zone
is activated while the system is unset, the system starts a pulsed
tone from the keypad. If programmed, the control unit also starts
communication. When a user enters a valid code, the keypad
stops the tone and displays the zone.
09 Keybox (KB) This zone type is for use in Scandinavia only. When a zone of
this type is required, the Installer connects the alarm wires of the
zone to a special external key box and the tamper wires to the
box enclosure switch. When someone opens the box, the
control unit logs the event and communicates it to the Alarm
Receiving Centre (ARC). The control unit also provides a Key
Box output type, which you can program with Command 151 to
trigger one of the plug-by communicator output pins.
10 Smoke
Detector (SD)
In Scandinavia only, use this type for zones connected to 12V
smoke detectors. This type is active whether the system is set or
unset, and the control unit will transmit a specific alarm to the
Alarm Receiving Centre (ARC) if triggered. The control unit also
provides a Smoke Detector output type, which you can program
with Command 151 to trigger one of the plug-by communicator
outputs. If a zone of this type causes an alarm, the user will
need to enter an access code to disarm and reset the system.