Engineering Manual Engineer Menu 1-4
53
The control unit operates the General Fault System Output at the same time as the RF
Jammed System Output.
151 – Tx Low Battery
The control unit operates this output when any MRNode reports a wirefree detector with
low battery. (There is a separate output type for Telecommands and PAs.) The output
remains on until all MRNodes stop reporting detectors with low batteries.
The control unit operates the General Fault System Output at the same time as the TX Low
Battery System Output.
152 – Telecommand Low Battery
The control unit operates this output when any MRNode reports a telecommand or PA
with low battery. The output remains on until all MRNodes stop reporting telecommands
or PAs with low batteries.
The control unit operates the General Fault System Output at the same time as the
Telecommand Low Battery System Output.
153 – Set Pulse
The control unit switches this output on for 10 seconds when a user sets any ward.
154 – Unset Pulse
The control unit switches this output on for 10 seconds when a user unsets any ward.
Ward Event Output Types
The following events are applicable if you have chosen the output to follow a specific ward:
00 – Bell-SAB
Activates when the selected ward is in alarm and the control panel bell output is on, and
deactivates when the bell output is off. The bell output may be activated on a confirmed
or unconfirmed alarm, depending on whether Bells on Confirm or Bells on Unconf is
selected (page 90).
01 – Strobe
Activates when the selected ward is in alarm and the control panel strobe output is on;
deactivates when the selected ward is reset.
02 – Switch 12
Activates when the selected ward is set; deactivates when the selected ward is in alarm, its
Entry Delay timer (page 61) is running or the ward is unset. This output is normally used as
an input to latching detectors.
03 – Det. Reset
Deactivates for approximately 4 seconds when a user code is entered to set the first ward.
The output is used to reset latching detectors (smoke detectors, shock sensors, etc.).
04 – Walk Test
Activates when the selected ward is walk tested (User option 1-1-2); deactivates when the
walk test is exited.