Engineer Menu 2-7 Engineering Manual
130
Option 2-7-3-5 – Checking the Status Network Devices
[
[
[
[
]
202
To select devic e:
· Press| or ¬ to scroll or,
Enter network and device number ( e.g.
201 for network 2 device 1.
Press] when you have finished.
Zone status
(T=Tamper, H=Healthy ,
A=Activ e, S=Shorted
M=Masked)
Radio zone statu s
(T=Tamper, H=Healthy ,
A=Active)
Radio jamming statu s
(Clear or Jammed)
Lid tamper status
(H=Healthy, A=Active)
Lid tamper status
(H=Healthy, A=Active)
Lid tamper status of any
attached keypad
(H=Healthy, A=Active)
Node Voltag e
Node Voltag e
Fuse status
(H=Healthy, B=Blown)
Device type
Equipment 5
Network Devices
2:01 Remote
A-T B-H T-H
2:02 MSNode
13.75 FH TH HH**
2:03 RNode
13.50 FH TH ****
2:03 Zone Status
1H2H3H4H5H6H7H8A
2:03 RNode
RF Clear
1. SELECT DEVICETO
VIEW STATUS
e.g.
Lid tamper status
(H=Healthy, A=Active)
Not applicable on
RNodes
Not applicable on RNodes
This option allows you to check the status of zones, tampers, fuses, etc. connected to devices on
the network. The information displayed depends on the device type. Note that MRNodes may
be listed as MSNodes for a short while after you first connect them to a network.
The keypad that you are using is the first device to be displayed.
Kommentare zu diesen Handbüchern