M2000 Installation Instructions 5
Network 1
Network 2
2000
CONTROL
PANEL
5 Outputs
8 Zones
8 Outputs
30 ID Zones
Wiring Option 3
MIDNode/IDNode
Maximum of 120 zones
with four MIDNodes.
Maximum of 40 zones
with two IDNodes.
MIDNode/ID Node
NOTE:
Do not connect an MSPSU,
MSNode, or MRNode directly
to the same network as an
MIDNode or keypad.
NOTE:
Do not connect an MSPSU,
MSNode, or MRNode directly
to the same network as an
MIDNode/IDNode.
Wiring Option 1
MSNodes
An MSNode/MSPSU is
capable of driving 4
Remote Keypads and
a Loudspeake r
100m max
100m max to
furthest keypad
1 km max
to furthest
MSNode
2 Outputs
8 Zones 8 Zones
Max 16
8 Zones
Max 4
1 Output
MRNode
2
MSNode
1
MSPSU
16
100m max
Wiring Option 2
Remote Keypads/LEC2s
Network Wiring = 6 Core
Max 5
100m max to
furthest
keypad/LEC2
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
1 Output
2 Zones
(see note
below)
Engineer’s keypad (cannot
have zones or outputs).
Note: When plugged in,
an engineer’s keypad is
connected to network 1.
This may interfere with the
corrrect function of any
attached
MSPSU,
MSNode, or MRNode
Figure 3: Overview of Network Wiring Options
Note:
• Using a Networker Interface Board (NIB) (with power supply) enables the maximum distance from a control panel to an ID Node or keypad to be
increased to 1km.
• The supply voltage at each Network 1 or 2 device must not drop below 10.5V (Cooper Security recommend that for reliable working while mains power
is present you should ensure that the voltage at each device is above 12.0V). Refer to the M2000/M800/M750 Engineering Manual for details of how to
calculate and overcome voltage drops.
• Direct connection of an LEC6 (6-zone) expander to Network 1 or 2 is supported for existing systems that are being upgraded. Ensure that the number
of zones does not exceed the number that would be provided by keypads alone.