12 M2000 Installation Instructions
Remote Reset Input
("12" in Figure 2.)
For alarms that require an engineer or remote reset,
the system can also be reset by applying 0Vdc to the
REM RST input terminal. This can be achieved by
routing 0V from terminal block "16" (Figure 2) through
a switch to the REM RST input.
This input could be connected to the "Control" output
from a RedCARE Subscribed Terminal Unit (STU) to
enable the central station to provide a "Remote Reset"
facility.
Extension Loudspeaker Connections
("13" in Figure 2.)
An extension loudspeaker can be connected to the
SPKR terminals of the control panel. Connection
details are shown in Figure 15.
The speaker output is designed to drive up to two 16
loudspeakers. However, when using two speakers, you
must wire them in series to reduce current
consumption.
Each loudspeaker output can also be programmed to
one or more wards so that the sounder only operates
under the relevant conditions.
Note: Extension loudspeakers MUST NOT be wired in
the same cable as used for network or zone wiring.
1 x 16 Ohm Loudspeaker
2 x 16 Ohm Loudspeakers
SPE
A
KER
SPEAKER
+
+
0V
0V
Figure 15: Extension Loudspeaker Connections
AC Input Connector
("14" in Figure 2.)
The two outer terminals of the AC IN connector
connect to the 20VAC output from the mains
transformer.
Battery Connector
("15" in Figure 2.)
Note: Do not connect the battery until all other wiring
has been completed.
The BATT terminals are for connection to a +12Vdc
standby battery. A battery lead is provided in the
spares pack (red wire to "+").
+
-
12V 17Ah Battery
+
_
Control Panel
battery terminals
Figure 16: Battery Connections
If the mains power to the control panel fails, the
standby battery will take over and maintain the
system. In order to safeguard the battery from full
discharge, the control panel automatically isolates the
standby battery when its voltage falls below 9.5V.
When the mains power is restored, the system will
power-up and continue to recharge.
12Vdc Auxiliary Power Terminals
("16" in Figure 2.)
You can use the terminal block in the bottom-left
corner of the control panel PCB to power devices such
as PIR detectors. The terminals provide 12Vdc.
Back Tamper Connector
("17" in Figure 2.)
The BACK TAMPER connector should be wired to the
"back tamper switch", which is mounted on a plate
that slides into slots shown in Figure 1. The switch
enables the system to generate a tamper alarm if the
lid of the control panel is removed or if the control
panel is removed from the wall.
Factory Restart Connector
("18" in Figure 2.)
If the pins of the FACTORY RESTART connector are
shorted during power-up, all system parameters are
reset to their factory default settings, including the
engineer passcode, as documented in the
M2000/M800/M750 Engineering Manual
.
Ensure that the terminals remain shorted until the
heartbeat LED (LED1) flashes.
Momentarily shorting the terminals with power already
applied defaults only the engineer passcode.
Note: This procedure will not work if an installer has
locked the NVM using option within the Installer