M2000 Installation Instructions 3
Introduction
Figure 1 and Figure 2 show the layout of the control
panel and the main features of the printed-circuit
board (PCB).
The panel includes a wealth of features, including:
Eight on-board zones.
Two network ports for the connection of keypads,
MSNodes and MRNodes (see Figure 3). The
additional network devices enable the system to
be expanded up to 264 zones.
Serial and USB connectors for local connection of a
PC running the Downloader configuration and
monitoring software.
An on-board modem connected to PSTN and RJ11
ports to enable remote connection to a remote
alarm receiving centre or to a PC running the
Downloader software.
Switched-positive, switched-negative and voltage-
free programmable outputs.
16-channel digital communicator outputs for
connection to an alarm receiving centre or to
provide additional programmable outputs.
Engineer keypad port.
CPA6 output port to provide additional
programmable outputs.
Serial printer port.
This leaflet describes how to install the control panel. If
you need a general overview of its features, please
refer to the
M2000/M800/M750 Engineering Manual
.
If you require details of how to install keypads or other
ancillary devices, please refer to their separate
installation instructions.
At the publication of this manual, the MKP1, CPA6,
MIDNode and IDNode are no longer available for sale.
This manual includes details of these products in case
you are fitting a M2000 control unit to older M-series
alarm systems with these products.
Note: Before connecting any external devices to the
control panel, make sure that it is able to provide
sufficient current to power such devices, as described
on page 14.
0
Fixing hole (1 of 3)
Printed circuit
board (PCB)
Fused terminal block Mains terminal block
Mains transformer
Back tamper
switch
mounting slots
Mains cable
entry ONLY
Battery
position
Fixing hole