3. Installation 9752 Installation Guide
Page 22 11976870
Zone 1
Zone 2
1
2
2K2 EOL
4K7
Alarm contacts
Tamper contacts
2K2 EOL
4K7
Alarm contacts
Tamper contacts
Figure 12. FSL Connections
Yellow
Violet
Red
Gold
4k7
Red
Red
Red
Gold
2k2
Figure 13. Colour Code for FSL Resistors
Anti-Masking Zone Connections
Note: Connecting an anti masking detector to the 9751 does NOT make the
9752 a Grade 3 control unit.
Some PIR detectors are fitted with an anti-masking facility to detect cases
where the detector has been obscured. Depending on the type of detector,
the masking status is conveyed by one of two methods:
Method 1: Using two pairs of contacts at the sensor. One pair reports the
alarm/tamper status and the other reports the anti-masking status. This
method requires two adjacent zones to be used at the 9752 control unit
(one for each pair of contact at the sensor), with the highest zone number
for anti-masking. For example, you could use zones 3 and 4, and in this
case, zone 3 must connect to the alarm/tamper contacts, and 4 to the anti-
masking contacts. The anti-masking zone (zone 4 in this example) must be
programmed as type "Anti-Mask". The alarm/tamper zone could, for
example, be programmed as type "Normal Alarm".
The anti-masking contacts from the sensor can connect to the 9752 using
the CCL, FSL or EOL connection method. In the case of FSL, there would
be no in-line tamper contacts (just the 2K2 end-of-line resistor and the 4K7
resistor across the anti-masking contacts). In the case of CCL, the zone's
tamper terminals at the 9752 must be shorted.
Method 2: Applying a specified resistance value to a zone. The zone must
be wired as shown in Figure 14.