4. Programming
496792 37
To change: Key-in: Notes Default
Set Time and Date 51 ..... see “Setting Time and Date”
Omit Tamper Allowed 52 0 Alarm contacts only Y
1 Alarm plus tamper contacts
Abort reset 53 0 Abort System Y
1 Abort User
BVVO Superv’n Response 54 0 Disabled
(9752 only) 1 Enabled
4/6 Digit Access Codes 56 0 Four digit codes Y
(9752 only) 1 Six digit codes
Battery Load Test 57 0 Disabled Y
(9752 only) 1 Enabled
Day Tamper Indication 58 0 User Reset Y
(9752 only) 1 Installer Reset
Sounder Tamper 59 0 Negative voltage tamper return Y
1 End of line 2k2 resistor.
Level B final exit 60 0 B=FE = FE (Final exit) Y
1 B=FE = NA (Normal alarm)
Level B Entry route 61 0 B=ER = ER (Entry route) Y
1 B=ER = FE (Start entry timer)
Level B Exit Mode 62 0 Timed plus Low Tone Y
1 Instant set
2 Silent set (kpd beeps at end of setting period)
3 Lock set
4 Exit mode same as Level A
Level B Alarm response 63 0 Keypad Sounder Only
1 Internal Sounder and keypad sounders Y
2 Local (all sounders, no comms)
3 Full alarm (all sounders and comms)
Level B Entry Time 64 1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level B Exit Time 65 1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Kommentare zu diesen Handbüchern