9651 Programming - Programming Commands
11772232 Page 51
65: Level B Exit Time
This command sets the Exit Time for Level B.
Option
1 10 seconds
2 20 seconds (default)
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
67: Forbikobler Approved
This command specifies whether the Forbikobler system should operate in an
approved manner (user codes only) or a non-approved manner (proximity
tags and user codes).
Option
0 Non-approved
1 Approved (default)
68: Forbikobler Door Timer
This command sets the time that the Forbikobler system allows for entry to
the building (not the time needed to unset the system). During this period, an
optional output is activated to operate an electromechanical lock on the door.
Option
0 2 seconds 5 20 seconds
1 3 seconds 6 30 seconds
2 4 seconds 7 60 seconds
3 5 seconds (default) 8 120 seconds
4 10 seconds 9 255 seconds
69: Forbikobler Door Locking
This command specifies whether the door controlled by the Forbikobler
system is normally unlocked while the system is reset or opened only for a
controlled time. Even if the door is normally unlocked, it can be locked with a
user command if required.
Option
0 Lock Timed (default)
1 Lock Toggled