Programming - Programming Commands 9651
Page 36 11772232
The following table shows the letters generated by each key on the keypad.
1 7 P Q R S
2 A B C Æ Å Ä 8 T U V
3 D E F 9 W X Y Z
4 G H I 0 Space ' ( ) : . - ! &
5 J K L C Move right
6 M N O Ø Ö D Move left
Zone Types
The following table shows the values available for zone type.
Value Type Description
00 Not Used
(NU)
Identifies zones that are not used. The system ignores zones of
this type. It is not necessary to link the circuit or anti-tamper
connections.
01 Panic Alarm
(PA)
Operating a device programmed as "Panic Alarm" will start
either a silent alarm transmission to the Alarm Receiving Centre
(ARC) or an audible alarm, depending on how you have
programmed PA Response (see Command 30). PAs operate,
whether the system is set or unset.
02 Fire (FR) Smoke or heat detectors connected to FR type zones cause the
speakers to give a distinctive fire signal (internal sounders
pulsing "Dee Dah Dee Dah..."). Fire alarms always operate,
whether the system is set or unset, and always trigger
communications if fitted.
03 Normal Alarm
(NA)
A zone programmed as "Normal Alarm" will start an alarm if
activated while the system is set.
04 24-hour (24) This zone causes an internal alarm if violated when the system
is unset, and a full alarm if the system is set. If the Installer
programs 24-hour zones with "Omit Allow", the user can omit
24-hour zones in Day mode. The control unit reinstates all 24-
hour zones if anyone sets the system.
05 Final Exit (FE) Zones of this type must be the first to be activated on entry. You
can use them to set the system using the Final Door Set exit
mode. Use Command 39 to set the exit mode for the zone (page
44). Use zone attribute X7 to select an entry timer for the zone
(page 39) and Commands 201–4 (page 65) to set up the entry
timers.
06 Entry Route
(ER)
Use this zone type for detectors sited between the Final Exit
door/detector and a keypad. If an "Entry Route" zone is violated
when the system is set, an alarm will occur. If the Entry/Exit
timer is running when an Entry Route zone is violated, no alarm
occurs until the Entry/Exit timer expires. Use zone attribute X7 to
select an entry timer for the zone (page 39) and Commands
201–4 (page 65) to set up the entry timers.
07 Shock
Analyser (SA)
You can apply this zone type to zones 1 to 4. The system will
not accept this type for zones 5 to 8. Use zone attribute X7 to
set the sensitivity for the zone (page 39).