9651 Programming - Programming Commands
11772232 Page 39
Value Attribute Valid for Description
X2
Soak Test (S) Normal Alarm
(NA)
Entry Route
(ER)
24-hour (24)
Shock Analyser
(SA)
Use this zone attribute if you want to place on
long-term test a detector that you suspect is
giving false alarms. Zones with this attribute
are disabled for 14 days after you return the
control unit to user mode. If the zone is
opened while the system is set (or at any time
for a 24-hour zone), the control unit logs the
event as a "Soak Fail Znn" (nn = zone
number) without sounding any bells or starting
signalling. The control unit returns the zone to
normal use after 14 days, even if the system
is set at the time.
X3
Double Knock
(D)
Normal Alarm
(NA)
Entry Route
(ER)
For zones with this attribute, no action is
taken on first activation. To cause an alarm,
the zone must be activated twice within a five-
minute period or remain open for longer than
10 seconds. An alarm will also occur if
another double-knock zone is activated within
five minutes of the first.
Programming a zone as "Double Knock" is a
way of reducing false alarms caused by
environmental changes but is not normally
recommended. Do not apply "Double Knock"
to radio zones with a PIR detector. The radio
PIR detector uses a lockout timer and will not
send a second activation within the Double
Knock period.
X4
Omit Allowed
(O)
All When applied to a zone, this attribute allows
the user to omit the zone when setting the
alarm. Do not allow the user to omit PA
zones.
Do not apply this attribute to an FE zone if
there is no ER zone present.
X5
Do Not Use.
X7
The meaning of this attribute depends on the zone type:
Shock
Analyser
Sensitivity
Shock Analyser
(SA)
You can set this attribute only for a zone of
type SA, and only zones 1, 2, 3 and 4 support
this type. To set the sensitivity of a shock
sensor zone, enter a digit in the range 1 (least
sensitive) to 6 (most sensitive). You must
enter the whole sequence; for example, to set
the sensitivity to 3, press X73
Entry Timer
Number
Final Exit (FE)
Entry Route
(ER)
Forbikobler
(FB)
To select which of the four entry timers (set
up using Commands 201–4, as described on
page 65) are used for the zone, enter a digit
in the range 1 to 4. You must enter the whole
sequence; for example, to select Entry Timer
3, press X73