4. Programming
496478 51
(which represents the “R” or Recall button on a tel-
ephone) which is detected by the exchange as a request
for a new clean line. With the new line available, the
communicator then attempts to connect to the pre pro-
grammed receiver number.
Download Mode (Command 110)
The 9750 can be programmed from a PC using <Downloader> software. You
can connect the PC to the control unit over the telephone network.
Key in 110 Y Y to manually accept a call from the PC.
You will also need to use commands 112, 113. (Note that Secure callback
does not work with this option.) The control unit will leave command 110 if
<Downloader> does not make a call within 30 minutes.
While the control unit is connected to the PC you can upload its programming
configuration into the <Downloader> in order to inspect it. Using
<Downloader> you can change the configuration and then transmit the new
configuration back to the control unit. If you do not wish to change the con-
figuration you can simply monitor the state of the control unit and zones from
the PC.
Use command 114 if you want the control unit to answer incoming calls from
<Downloader> without an engineer being present.
Rings to Answer (Command 112)
Use this option to set the number of rings that the system waits before
answering an incoming call from the remote PC. See “Programming Com-
mands” for the available options.
Answer on One Ring (Command 113)
(Answer phone defeat) Use this feature if the alarm system shares a line with
other equipment.
One ring off (0) Disabled
One ring on (1) <Downloader> “warns” the alarm system that a call is
coming by ringing the alarm system number, waiting for
between one and two rings and then hanging up. The
alarm system now knows to expect a call within the next
10 to 90 seconds. <Downloader> then rings the alarm
system again, within 10 to 90 seconds. The alarm system
answers after the first ring.
Note: When using "Answer on 1 Ring" set the number of rings in "Rings to Answer"
(C112) to a higher number than that used by the equipment sharing the
telephone line with the alarm system. If you do not, then the other equipment
will never answer any incoming calls.