4. Programming
60 496791
set B will continue to act as Final Exit zones during part set B. When the
option is set to 1 any Final Exit zones included in part set B will act as Normal
Alarm zones during part set B.
Level B Entry Route Response (Command 61)
Command 61 controls how the system treats Entry Route zones during part
set B. (This Command does not affect Partition B in a Partitioned system.)
When the option is set to 0 all Entry Route zones included in part set B will
continue to act as Entry Routes during part set B. When the option is set to 1
any Entry Route zones included in part set B will act as Final Exit zones
during part set B.
Level B Exit Mode (Command 62)
Command 62 specifies the exit mode for part set B or Partition B. For a
single system the options are:
Option 0 The keypad sounders and any internal sounders give a low tone
when entering part set Level B. Use Command 65 to select the
exit time.
Option 1 Instant Set (no exit tone)
Option 2 Silent Set. Use Command 65 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 3 Makes the Level B exit mode the same as Level A.
For a partitioned system the options are:
Option 0 (UK default) The keypad sounders and any internal sounders give
a full tone when setting Partition B. Use Command 65 to select the
exit time.
Option 1 Terminate. Use this option if the user completes setting the
Partition by pushing an exit terminate button connected to a
keypad. Note that the exit time is infinite in this option.
Option 2 Final door set. Use this option to complete setting the Partition by
closing a door fitted with a Final Exit zone detector. Note that the
exit time is infinite in this option.
Option 3 Instant Set (no exit tone)
Option 4 Silent Set. Use Command 65 to program the Exit time. At the end
of the exit time the keypad gives a double beep confirmation tone.
Option 5 Lock Set. See “Level A Exit Mode (Command 39) for an explana-
tion of Lock Set.
Note that the keypads give a double beep confirmation tone at the end of all