4. Programming
496791 35
To change: Key-in: Notes Default
Tamper Alarm Response 46 0 Internal sounders
(Single system only.) 1 Keypad sounders
2 Internal and keypad sounders Y
Part’n A Alarm Response 47 0 Keypad sounders
(Partitioned system only.) 1 Local Alarm
2 Full Alarm Y
Lockout Kpds During Entry 48 0No
1 Yes
CSID Code 50 n....n Seed code for remote reset none
Set Time and Date 51 ..... see “Setting Time and Date”
Omit Tamper Allowed 52 0 Alarm contacts only Y
1 Alarm plus tamper contacts
Abort reset 53 0 Abort System Y
1 Abort User
BVVO Superv’n Response 54 0 Disabled Y
1 Enabled
4/6 Digit Access Codes 56 0 Four digit codes Y
1 Six digit codes
Battery Load Test 57 0 Disabled Y
1 Enabled
Day Tamper Indication 58 0 User Reset Y
1 Installer Reset
Sounder Tamper 59 0 Negative voltage tamper return Y
1 End of line 2k2 resistor.
Level B final exit operation 60 0 B=FE = FE (Final exit) Y
1 B=FE = NA (Normal alarm)
Level B Entry route 61 0 B=ER = ER (Entry route) Y
1 B=ER = FE (Start entry timer)
Level B Exit Mode 62 n
For a single system n is one of the following:
0 Timed plus low tone Y
1 Instant set
2 Silent set (kpd beeps at end of setting period)
3 Exit mode same as Level A
For a partitioned system n is one of:
0 Timed full tone Set (default) 3 Instant set
1 Terminated 4 Silent (kpd beeps at end of setting period)
2 Final door 5 Lock Set