Log Messages
11980075 Page 27
Message Meaning
System Tamp
Rst
System tamper reset
System Tamper System tamper
Tamper F== Rstr Forbikobler keypad == tamper
reset
Tamper K==
Rstr
Keypad == tamper reset
Tamper Z== Zone == tampered with
Tamper Z== Tamper in zone == during the
day
Tamper Z== Rstr Zone == tamper reset
Tech Z== Alarm Technical alarm in zone ==
Tech Z== Rstr Technical alarm in zone ==
reset
Tel Line Fault Line fault on telephone line
Tel Line Rstr Line fault reset on telephone
line
U== # Set User == set level #
U== # UnSet User == unset level #
U== Change
U==
User == changed access code
for user ==
U== Delete U== User == deleted access code
for user ==
U== Duress Duress code entered by user
==
U== Off-Site Installer exited from
programming mode
U== On-Site Installer entered from
programming mode
U== System
Reset
User – reset system
U== Time/Date Time and date user reset the
system
U== Z== Omit User omitted zone ==
U== Z== Unomit User unomitted zone ==
UserCode req off No user code before installer
code
UserCode req on User code before installer
code
XT ACFl Rst Z== Mains power supply restored
in zone ==
XT ACFl Z== Mains power supply failed in
zone ==
XT BatFl Rst
Z==
Battery reconnected in zone
==
XT BatFl Z== Battery fault in zone ==
Message Meaning
XT Fault Z== Rst Zone of type ‘Fault’ reset
XT Fault Zone
==
Zone of type ‘Fault’ active
XT PwrFl Rst
Z==
Power output fault reset in
zone ==
XT PwrFl Z== Power output fault in zone ==
Z== Lock Out The system locked out the
zone when attempting to rearm
a the end of the bell run time.
Z== Lock Out
Rst
The system restored a locked
out zone.